IR Thermometer & K - Thermocouple Product - TCT103F
Specification
Model No |
TCT103F
|
| Measurement range |
-33~220°C(
-27~428°F) |
Infrared Accuracy (Tamb=23+/ -3°C)
|
(Tobj=0~ 65°C): +/-1.5°C ,else +/2% or 2°C(4°F) |
| Thermocouple Accuracy |
(Tobj=-9~100°C)±0.5 °C (0.9°F) ,
else ±0.9% of reading or 0.8°C (1.4 °F)
|
| Distance: Spot |
1:1 |
Mode
|
Max, Min, Lock
|
Feature
- NIST traceable
- Certificate of Calibration Available (COC Optional)
- IR-SoC technology (Infrared System on Chip) and Batch Calibration technology drive the dimensions and cost to the lowest limits
- 2in1, Infrared + Thermocouple = Instant + Accurate
- Adjustable Emissivity
- Max; Min and Lock modes
- Retractable probe
- Dual Display
- Auto Power Off
Available Packages
ME1 (MetalBox) |
Packing List
|
 |
 |
One set includes:
- Infrared thermometer
- 1 CR 2032 battery
(inside the thermometer)
- 1 user manual
- Metal box with foam inlay
- White box (paper)
- COC (optional)
72 box/carton
Carton size:
436*406*390 mm
(2.44 cube ft)
N.W.:16.50kgs; G.W.:17.47kgs |
BL1 (Blister) |
Packing List
|
 |
 |
One set includes:
- Infrared thermometer
- 1 CR 2032 battery
(inside the thermometer)
- 1 user manual
- Blister with inlay card
- COC (optional)
42 box/carton
Carton size:
578*315*454 mm
(2.91 cube ft)
N.W.:6.08kgs; G.W.:8.32kgs |
CL1 (Color Box) |
Packing List |
 |
 |
One set includes:
- Infrared thermometer
- 1 CR 2032 battery
(inside the thermometer)
- 1 user manual
- Color box (paper)
- COC (optional)
- Bubble bag (for protection)
100 box/carton
Carton size:
395*412*373 mm
(2.14 cube ft)
N.W.:11.09kgs; G.W.:12.71kgs |
WH1 (WhiteBox) |
Packing List |
 |
 |
One set includes:
- Infrared thermometer
- 1 CR 2032 battery
(inside the thermometer)
- 1 user manual
- White box (paper)
- COC (optional)
- Bubble bag (for protection)
100 box/carton
Carton size:
395*412*373mm
(2.14 cube ft)
N.W.:11.09kgs; G.W.:12.7kgs |
WS1 (Holster) |
Packing List
|
 |
 |
One set includes:
- Infrared thermometer
- 1 CR 2032 battery
(inside the thermometer)
- 1 user manual
- Holster
- White box (paper)
- COC (optional)
- Bubble bag (for protection)
100 box/carton
Carton size:
510*434*373 mm
(2.92 cube ft)
N.W.: 12.55kgs; G.W.:14.05kgs |
General Description
Infrared thermometers with built in contact type thermocouple probe.
This dual sensors thermometer can be very useful while both non-contact and contact temperature measurements are required.
Some models with food grade requirement are specially designed for food service application.
Available Probes: The hot junction is grounded to the sheath.
Response Time TSR (Test Report)

Typical Error of Reading
A typical error of reading is not a simple figure, it's a function of Tobj (object temperature) & Tamb (ambient temperature)
Because Infrared Thermometer is a "Relative" measurement instrument. (It compares the Tobj against Tamb)
So, the error has a minimum value when Tobj ~ Tamb,
that is when you measure something close to ambient temperature.
For ZyTemp, this minimum value (dTabs) = 0.15°C / 0.27°F ,
usually, our competitor is larger than 0.2°C / 0.36°F
At higher or lower temperature, there is a Gain Error, usually 2%.
Q: Since the spec is "+/-2°C or 2%", is IRT most accurate at Tobj=0°C?
A: No, as described as above, IRT use a "Relative" measurement, IRT is most accurate at Tobj=Tamb,
In other words, when you point the IRT at a "near room temp" object, it will be very accurate.
Q: Can I calibrate my IRT by pointing it to a wall (25°C)?
A: No, even though the Gain run away, the IRT still shows 25°C, you have to use a "Temperature Different From Tamb",
(ex. 0°C or 50°C) 0°C is the most available temperature "standard", for ordinary user.

Certificate of Calibration