Catalog
Press Release
Home
About Us Quality System Products Support Infrared Know How Contact Us Where to buy
ZyTemp A new way to measure temperature Logo
TEL: +886 3 611 1666 FAX: +886 3 564 4170 Site Map , E-mail , Chinese
Site Map http://wwwZyTemp.com.cn E-mail
TN002Ci
TN002Ki
TN006c

TN004 TN006

TN005 TN007
TN105B TN105C
TN105i2
TN105J
TN110g
TN110rb
TN102B
TN103
TN104
TN102
TN15A
TN153
TN159
TN185
  TN602C

TN205 TN205L

TN253L
TN253LF

TN400L TN400L1 TN403L

TN408LC
TN408LC TN408LT
TN40ALC
TN410LA TN410LB TN410LC TN410LD
TN410L9
TN410L2 TN410L3
TN418LA TN418LB TN418LC TN418LD TN418L9
TN418L0 TN418L1 TN418L2 TN418L3
TN423LC
TN425LC
TN458LC
TN468LC
TCT303F
TCT012
TCT013
  TCT103 Infrared Thermometer & Thermocouple Thermometer
TCT103
 
 
2in1 , Infrared + Thermocouple
Specifications
Feature
Available Packages
Available Colors
Anti-Thermal Shock Feature
General Description
Applications
Available Probes
Response TimeTest Report
Typical Error of Reading
Certificate of Calibration
Download Label ( CDR file / PDF file )
Download Spec. (TN Family Selection Guide PDF file)
  Specifications
   
 
Model No
TCT103
TCT103F
Measurement range
--33~220°C
-27~428°F
--33~220°C
-27~428°F

Accuracy (above -33°C)

+/-2%,2°C#Acm
(-33~220°C)
+/-1.5°C(0~65 °C)
Distance: Spot
1:1
1:1
Mode
Max,Min,Lock
Max,Min,Lock
 
     
  Feature
NIST traceable
Certificate of Calibration Available (COC Optional)
IR-SoC technology (Infrared System on Chip) and Batch Calibration technology drive the dimensions and cost to the lowest limits
2in1, Infrared + Thermocouple = Instant + Accurate
Emissivity Adjustable
Max; Min and Lock modes
Retractable probe
Dual Display
Auto Power Off
  Available Packages
Cpac: ME1 (MetalBox)
Packing List

One set includes:

  • Infrared thermometer
  • 1 CR 2032 battery (inside the thermometer)
  • 1 user manual
  • Metal box with foam inlay
  • White box (paper)
  • COC (optional)

72 box/carton
Carton size:436*406*390 mm
(2.44 cube ft)
N.W.:16.50kgs; G.W.:17.47kgs

Cpac: BL1 (Blister)
Packing List

One set includes:

  • Infrared thermometer
  • 1 CR 2032 battery (inside the thermometer)
  • 1 user manual
  • Blister with inlay card
  • COC (optional)

42 box/carton
Carton size: 578*315*454 mm
(2.91 cube ft)
N.W.:6.08kgs; G.W.:8.32kgs

Cpac: CL1 (Color Box)
Packing List

One set includes:

  • Infrared thermometer
  • 1 CR 2032 battery (inside the thermometer)
  • 1 user manual
  • Color box (paper)
  • COC (optional)
  • Bubble bag (for protection)

100 box/carton
Carton size: 395*412*373 mm
(2.14 cube ft)
N.W.:11.09kgs; G.W.:12.71kgs

Cpac: WH1 (WhiteBox)
Packing List

One set includes:

  • Infrared thermometer
  • 1 CR 2032 battery (inside the thermometer)
  • 1 user manual
  • White box (paper)
  • COC (optional)
  • Bubble bag (for protection)

100 box/carton
Carton size: 395*412*373mm
(2.14 cube ft)
N.W.:11.09kgs; G.W.:12.7kgs

Cpac: WS1 (Holster)
Packing List

One set includes:

  • Infrared thermometer
  • 1 CR 2032 battery (inside the thermometer)
  • 1 user manual
  • Holster
  • White box (paper)
  • COC (optional)
  • Bubble bag (for protection)

100 box/carton
Carton size: 510*434*373 mm
(2.92 cube ft)
N.W.: 12.55kgs; G.W.:14.05kgs

Note: The actual color may be different from the real product.
 
  Available Colors
Color: WWG1
(UC=White, RC=White, Key=Gray)
Color: WWB1
(UC=White, RC=White, Key=Blue)
  Anti-Thermal Shock Feature

IRT(Infrared Thermometer) is an instant magic, but when you take it from outdoor to indoor (or from one room to another room). You have to wait 30 minutes. "30 minutes" is absolutely not "instant". Most of IRT are plagued by such flaw.

By Many-year-experience in high precision clinical infrared thermometer (in EN12470, Error due to 10degC thermal shock must be less than 0.2degC!)
Finite Element Analysis of heat transfer; ZyTemp had overcome this barrier.

A simple test , according to test method described in in EN12470 Paragraph 7.6 Testing for compliance of accuracy under changing environmental conditions.,
clearly show that our ZyTemp TCT1 out perform the competitor's model, which usually has a price tag much higher than TCT1.

Error of M model can reach 1.6degC and require 30minutes to stabilize, while TCT1 is only 0.7degC and stabilize in 7minutes.

Such a test can be easily performed , even you don't have a standard & stable blackbody:
Setup a very stable target . Hint: use a large milk bottle (2 liter), fill in with water, wait 3 hours to stabilize, that's a very stable target, with thermal time constant about 100 minutes
Put the IRT outdoor (say 15degC), for 1 hours.
Bring IRTs back to indoor (say 25degC),
Measure the temperature of the Bottle by the IRT, every minute.
You will found the reading drift within 30 minutes, unless it's a ZyTemp Anti-Thermal Shock IRT: TCT102 or TCT103.
  ThermaTwin General Description

ThermaTwin Overview
ThermaTwin is the ideal multi-purpose tool for temperature measurements. It contains two reliable sensors:

  • An infrared sensor made through a micro machining thermopile process.
  • A Teflon-coated stainless steel probe, which acts as a thermocouple.

This dual function tool fulfills most temperature measurement requirements. The non-contact IR sensor can be used for instantaneous, hard-to-reach, and surface-oriented measurements. The thermocoupler functions as the dual of the former: accurately measuring subsurface temperatures.

More Sensors at Lower Cost
ThermaTwin implements an innovative technology, placing integrating two sensors seamlessly into one package. They share the same preamplifier, precision analog to digital converter (ADC), CPU, and LCD. Thus, making the cost of the thermometer the same as if there were only one sensor.

One can discover the emissivity of an object with the ThermaTwin. Simple use the ThermaTwin's metal rod to touch that object to get the (contact) temperature, then use the non-contact sensor to obtain that surface temperature. Later, adjust the emissivity until the thermometer displays the same temperature. Now you know the correct emissivity of the object.

ThermaTwin offers several different kinds of probes:

  • Penetration: for insertion into the interior of an object
  • Needle: a sharp penetrating probe that produces a fast response
  • Air
  • Liquid: similar to penetration, but with a round tip
  • Surface

The ThermaTwin is designed for many types of applications:

  • Hazard Analysis and Critical Control Point (HACCP)
  • Heater Ventilation and Air Conditioning (HVAC)
  • Science lab
  • Classroom
  • Kitchen

The Certificate of Calibration for the ThermaTwin is available upon request.

  Applications
  Available Probes: The hot junction is grounded to the sheath.
Probe Type
TTC
Response Time
Available
Relative
Price
US$
Photo
Type
Description
In Water
In Water (Food Grade)
In Air
In Water
In Water (Food Grade)
In Air
LQ
Liquid
NA
NA
30
NA
NA
69
103
1.0
ND

Needle,Diameter
=3.3+/-0.05mm
Tip Diameter < 2.2mm

2
1.5
30
4.5
3.5
69
102
1.0
PB
Penetration Blunt
6
4.2
30
13.8
9.7
69
102/103
0.0
PN
Penetration type
6
4.2
30
13.8
9.7
69
102/103
1.0
AR
for Air temperature measurement
NA
NA
TBD
NA
NA
TBD
103
1.0

Note: Relative Price is compared against PB type (our standard type)
TTC= Thermal Time Constant [sec] Response Time(90%)= TTC*2.3

  Response Time TSR (Test Report)
Response Time TSR (Test Report)
  Typical Error of Reading

A typical error of reading is not a simaple figure, it's a function of Tobj (object temperature) & Tamb (ambient temperature)
Because Infrared Thermoemter is a "Relative" measurement instrument. (It compare the Tobj against Tamb)
So, the error has a minimum value when Tobj ~ Tamb,
that is when you measure something close to ambient temperature.
For ZyTemp, this minimum value (dTabs) = 0.15°C / 0.27°F ,
usually, our competitor is larger than 0.2°C / 0.36°F

At higher or lower temperature, there is a Gain Error , usually 2%.

Q: since the spec is "+/-2°C or 2%", so IRT is most accurate at Tobj=0°C?
A: No, as described as above, IRT use a "Relative" measurement, so IRT is most accurate at Tobj=Tamb,
In other word, when you pointing the IRT at a "near room temp" object, it will be very accurate.


Q: I can calibrate my IRT, by point it to a wall (25°C)?
A: No, even the Gain run away, the IRT still will show 25°C, you have to use a "Temperature Different From Tamb",
for example 0°C or 50°C
0°C is the most available temperature "standard", for ordinary user.

  Certificate of Calibration

<