TN418LA(E)/TN418LB(E)/TN418LC(E)/TN418LD(E)/TN410L9(E) |
Dual Lasers
|
Thermocouple Probe (optional )
|
Bead (optional ) |
 |
 |
 |
TN418LR |
Relative Humidity
|
RH Display
|
DP Display |
 |
 |
 |
Specification
Model No |
TN418LA(E) |
TN418LB(E) |
TN418L9(E) |
| Measurement range |
-60~760°C(-76~1400°F)
|
Full Range Accuracy
(Tamb=23±3 °C) |
Tobj=-60~0°C,
+/-(2°C+0.05/ degree) ,
Tobj=0~760°C,
+/-2% of reading or 2°C(4°F)
whichever is greater |
Tobj=0~760°C,
+/-2% of reading or 2°C(4°F)
whichever is greater,
Tobj=-60~0°C,
+/-(2°C+0.05/ degree)
|
| Distance: Spot |
20:1 |
30:1 |
12:1 |
| Mode |
Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock |
Model No |
TN418LC(E) |
TN418LD(E) |
| Measurement range |
-60~500°C(-76~932°F) |
-60~625°C(-76~1157°F)
|
Full Range Accuracy
(Tamb=23±3 °C) |
Tobj=-33~500°C,
+/-2% of reading or 2°C(4°F)
whichever is greater |
Tobj=0~625°C,
+/-2% of reading or 2°C(4°F)
whichever is greater,
Tobj=-60~0°C,+/-(2°C+0.05/ degree) |
| Distance: Spot |
12:1 |
16:1 |
| Mode |
Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock |
Model No |
TN418LR |
| Measurement range |
-60~500°C(-76~932°F) |
Full Range Accuracy
(Tamb=23±3 °C) |
Tobj=-33~500°C,+/-2% of reading or 2°C(4°F)whichever is greater |
Relative Humidity
(Tamb=23+/-5degC) |
1~99%, accuracy: +/-3% from 20~80%, otherwise+/-5% |
| Dew point |
-50~50°C, accuracy: ±2.5°C from 20~30%RH;
±2°C from 31~40%RH; ±1.5°C from 41~95 %RH |
| Distance: Spot |
12:1 |
| Mode |
Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock |
Feature
- Select operating modes and adjust parameters easily
- Built-in jack support and K-type TC probe with "mini" style connector
- With White LED Flashlight (Optional)
- Various Measurement Range & DS Ratio optional
- With Relative Humidity (TN418LR Only)
Available Packages
BL1 (Blister) |
Packing List |
 |
 |
One set includes:
- Infrared thermometer
- 2 AAA battery
- 1 user manual
- Blister
- COC (optional)
- Pouch (optional)
- Bead (optional)
18sets/master carton
Master carton size:
502* 315* 485mm
( 2.7cube ft)
N.W: 7.5kgs
G.W: 8.8kgs
|
WH1 (WhiteBox) |
Packing List |
 |
 |
One set includes:
- Infrared thermometer
- 2 AAA battery
- 1 user manual
- WhiteBox
- COC (optional)
30sets/master carton
Master carton size:
531*365*440mm ; 3.0Cube ft
N.W: 12.15kgs
G.W: 13.7kgs |
General Description
TN418LA(E)/TN418LB(E)/TN418LC(E)/TN418LD(E)/TN418L9(E) are the ultimate tools for temperature measurements.
It contains 2 most reliable temperature sensors:
1) Non-contact Micro Machining Thermopile
2) K-type thermocouple socket
Such an arrangement can fulfill most of temperature measurement requirements:
Use the Non-contact for instant; not-reachable situation.
Use the thermocouple for high precision; non-surface situation.
Templorer also come with an ultra long battery life (8days for Alkaline battery), no 9V battery,
It use the most affordable and available AAA size battery.
Learn Emissivity with the Templorer: Emissivity is a difficult concept for general user to catch; For Templorer,
it's easy to get. Use the contact thermometer to get the true temperature.
Then, use the Non-contact to get the surface temperature. Adjust the Emissivity until they are the same.
Next time, use the correct Emissivity for that object. No more guess work, no more looking up on Emissivity Table.
TN4 Infrared Thermometer (Laser Thermometer) FOV Test / D:S Test.
Certificate of Calibration