ZyTemp_logo
Home > product > Infrared Hand Held > Gun Type > TN475LC(E)/ TN425LN(E)/ TN425LM(E)/ TN425LB(E)/ TN425LA(E)/ TN425LC(E)/ TN425L(E)

Product

Dual Lasers Infrared Thermometer - TN475 / TN425 Series

Dual Lasers

Built-in Socket
(optional)

Memory Mode <TN425LN(E)/ TN425LM(E)>

Specification

Model No

TN475LC(E)

Description IRT + Dual Lasers + Thermocouple socket, (E) with LED Flashlight (optional)
Measurement range -60~1600°C (-76~2912°F)
Full Range Accuracy
(Tamb=23+/-3°C)
Tobj=0~1600°C: ±2% of reading or 2°C (4°F) whichever is greater ;
Tobj=-60~0°C: ±(2°C+0.05/°C)
Distance: Spot 75:1
Mode Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock
Thermocouple Probe Small Socket, K type, 12 minutes auto power off
Measurement Range* -60~1400°C (-83.2~2552 °F)
Probe Accuracy ±1% of reading or 1°C(1.8°F) whichever is greater (Test under Tamb=23±6°C)

Model No

TN425LN(E)

TN425LM(E)

Description IRT + Dual Lasers + Thermocouple socket, (E) with LED Flashlight (optional)
Measurement range -60~1500°C (-76~2732°F) -60~1000°C (-76~1832°F)
Full Range Accuracy
(Tamb=23+/-3°C)
Tobj=-33~1500°C:
±2% of reading or 2°C(4°F)
whichever is greater
Tobj=-33~1000°C:
±2% of reading or 2°C(4°F)
whichever is greater
Distance: Spot 50:1
Memory Detailed 24 Memories with Temperature & Emissivity
Mode Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock
Thermocouple Probe Small Socket, K type, 12 minutes auto power off
Measurement Range* -60~1400°C (-83.2~2552 °F)
Probe Accuracy ±1% of reading or 1°C(1.8°F) whichever is greater (Test under Tamb=23±6°C)

Model No

TN425LB(E)

TN425LA(E)

Description IRT + Dual Lasers + Thermocouple socket
Measurement range -60~1500°C (-76~2732°F) -60~1200°C (-76~2192°F)
Full Range Accuracy
(Tamb=23+/-3°C)
Tobj=-33~1500°C:
±2% of reading or 2°C(4°F)
whichever is greater
Tobj=-33~1200°C:
±2% of reading or 2°C(4°F)
whichever is greater
Distance: Spot 50:1
Mode Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock
Thermocouple Probe Small Socket, K type, 12 minutes auto power off
Measurement Range* -60~1400°C (-83.2~2552 °F)
Probe Accuracy ±1% of reading or 1°C(1.8°F) whichever is greater (Test under Tamb=23±6°C)

Model No

TN425LC(E)

TN425L(E)

Description IRT + Dual Lasers + Thermocouple socket IRT + Dual Lasers
Measurement range -60~1000°C (-76~1832°F) -60~1000°C (-76~1832°F)
Full Range Accuracy
(Tamb=23+/-3°C)
Tobj=-33~1000°C:
±2% of reading or 2°C(4°F)
whichever is greater
Tobj=-33~1000°C:
±2% of reading or 2°C(4°F)
whichever is greater
Distance: Spot 50:1
Mode Ave, Dif, Hi/Low Alarm, Real Time Max / Min, Lock
Thermocouple Probe Small Socket, K type, 12 minutes auto power off --
Measurement Range* -60~1400°C (-83.2~2552 °F) --
Probe Accuracy ±1% of reading or 1°C(1.8°F) whichever is greater (Test under Tamb=23±6°C) --
*Actual temperature range depends on the TC probe selected.

Feature

  • Infrared up to 1600°C
  • Dual Laser Points for the Target Spot Size
  • High DS (Distance to Spot) Ratio up to 75:1 (TN475)/ 50:1 (TN425)
  • Detailed 24 Memories with Temperature & Emissivity <TN425LN(E)/ TN425LM(E)>
  • Mini Thermocouple Socket up to 1400°C(optional)
  • Best Cost/Performance Ratio
  • Large LCD display with Power Backlight
  • Min, Max, Dif, Ave, Lock Modes
  • Hi/Lo Temperature Audible Alarm
  • White LED Flashlight (optional)
  • Laser/LED and Backlight On/Off Control
  • Emissivity Adjustable from 0.1 to 1.00 (Preset at 0.95)
  • °C/°F Switch Mode
  • Magnet Stand (optional)
  • Long Battery Life with two AAA Batteries

Available Packages

TL1 (Tool Box)

Packing List

One set includes:

  • Infrared thermometer
  • 2 AAA batteries
  • 1 user manual
  • Tool Box
  • COC (optional)
  • Bead (optional)
  • Magnet Stand(optional)

14sets/master carton
Master carton size:
497*420*340mm (2.5 cube ft)
N.W:13.0kgs
G.W:15.0kgs

TL2 (Tool Box)

Packing List

One set includes:

  • Infrared thermometer
  • 2 AAA batteries
  • 1 user manual
  • Tool Box
  • Thermocouple Probe
  • COC (optional)
  • Magnet Stand(optional)

5sets/master carton
Master carton size:
500*430*350mm (2.65 cube ft)
N.W:8.825kgs
G.W:10.06kgs

Note: The actual color may be different from the real product.

General Description

TN475LC(E)/TN425LN(E)/TN425LM(E)/TN425LB(E)/TN425LA(E)/TN425LC(E) are the ultimate tools for temperature measurements.
It contains 2 most reliable temperature sensors:
1) Non-contact Micro Machining Thermopile
2) K-type thermocouple socket

Such an arrangement can fulfill most of temperature measurement requirements:
Use the Non-contact for instant; not-reachable situation.
Use the thermocouple for high precision; non-surface situation.

Templorer also come with an ultra long battery life (8days for Alkaline battery), no 9V battery,
It use the most affordable and available AAA size battery.

Learn Emissivity with the Templorer: Emissivity is a difficult concept for general user to catch; For Templorer, it's easy to get. Use the contact thermometer to get the true temperature.
Then, use the Non-contact to get the surface temperature. Adjust the Emissivity until they are the same.
Next time, use the correct Emissivity for that object. No more guess work, no more looking up on Emissivity Table.

TN4 Infrared Thermometer (Laser Thermometer) FOV Test / D:S Test.

Certificate of Calibration

Founded in July 2000, ZyTemp belongs to world-class Infrared Technology-oriented thermometer manufacturer - Radiant Innovation Inc. and become a premier provider of infrared temperature measurement devices. Originally started from a professional team of engineers specializing in infrared thermometry, this company is now emerging as worldwide well-known manufacturer of infrared thermometers (IRT).

Copyright (c) 2000-2018 RADIANT INNOVATION INC.
All Rights Reserved.